【Characteristic】
- Easy operation and touch display by touch panel.
- Easy to move (wheel mounted type)
- If you use the dedicated software, you can operate from your smartphone or tablet PC.(option)
【Usage】
For removal and deodorization.
Volatile organic compound (VOC) gases such as toluene, xylene, ethyl acetate
Exhaust gas of odor generating device.
Application Case
Various printing related, ink manufacturing, packaging material manufacturing, plastic product manufacturing, chemical adhesive manufacturing, various research institutes, semiconductor, liquid crystal manufacturing, universities, research institutes, etc.
Specification
MODEL | SCU-1EH |
Treatment Volume | 1N㎡/min |
Utility | 200V、3φ、50/60Hz、40A |
Catalytic amount | 3.375 liters |
Apparatus Dimensions | (W) approx. 1,271 x (D) approx. 494 x (H) approx. 1,096 mm (Blower, filter unit, including caster) |
weight | Approx 90 kg (Blower, filter unit, including caster) |
Heater output | 5kw |
Treatment blower | 0.13kw |
Inlet / Exhaust Outer | Diameter 78φmm / 125φmm |
Processing temperature
(Catalyst inlet temperature) |
300 ~ 350 ℃ (Setting can be changed) |
Installation location | Indoor |
touch panel | Start / stop the device (switch or timer)) Display of pre-catalyst temperature and air volume setting Post-catalyst temperature and power display Temperature, wind volume, electricity quantity trend graph |
Specification
Model | SCU-3EH |
Treatment Volume | 3N㎡/min |
Utility | 200V、3φ、50/60Hz、60A |
Catalytic amount | 6.75 liters |
Dimensions | (W) approx. 1,665 x (D) approx. 715 x (H) approx. 1,965 mm (Blower, Filter, Caster included) |
Weight | 200kg (Blower, Filter, Caster included) |
Heater output | 12kw |
Treatment blower | 0.75kw |
inlet / outlet | diameter 100φmm / 148φmm |
Processing temperature
(Catalyst inlet temperature) |
300 ~ 350 ℃ (Setting can be changed) |
Installation location | Indoor |
touch panel | Start / stop the device (switch or timer) Display of pre-catalyst temperature and air volume setting Post-catalyst temperature and power display Temperature, wind volume, electricity quantity trend graph |